Opening the lab
Boyle’s law is about a fixed mass of gas kept at a constant temperature. You trap some air in a glass tube, squeeze it with a pump, and measure its pressure and its volume together. The question is how one changes when you change the other.
The aim in Paper 3 is: to determine the relationship between the pressure and the volume of a fixed mass of gas at constant temperature.
For a fixed mass of gas at constant temperature, the pressure is inversely proportional to the volume.
P V = constantFor a gas going from one state to another: P1V1 = P2V2.
Example. A 40 cm³ column of air at 100 kPa is squeezed to 25 cm³. Then P2 = 100 × 40 ÷ 25 = 160 kPa.
This lab is a model. The air obeys P V = 4000 kPa cm³ exactly (40 cm³ at 100 kPa). The warming, the 2 minute settling time and the leak are built in with believable numbers, not measured from a real tube.
Yes. P × V is constant, so P = constant × (1/V). P is directly proportional to 1/V, and zero in gives zero out.
So draw your line of best fit through (0, 0), with the points scattered a little either side of it. That scatter is human error, such as reading the meniscus slightly high or low.
If your line misses the origin, something is wrong. The likely cause here is a systematic error in P: a gauge that leaves out the atmosphere makes every pressure too small by the same amount, so the line cuts the P axis below zero.
Gas pressure comes from molecules hitting the walls. Squeeze the same molecules into half the volume and they hit the walls twice as often, so the pressure doubles. That only holds if they keep the same speed, which means the same temperature.
Squeezing air does work on it, so it warms up. Warm air at the same pressure takes up more space, so V reads too big and P × V comes out too high. Heat slowly escapes to the room. In this lab the extra warmth fades with a time constant of 40 s, so after 2 minutes only about 5% of it is left.
| Precaution | Why |
|---|---|
| Air sealed by the oil, pump tightly connected | Air that leaks out changes the mass of gas. |
| Wait 2 to 3 minutes before each reading | The temperature must come back to room temperature. |
| Eye level with the meniscus | Avoids a parallax error in V. |
| At least six pairs of readings | Gives a reliable line of best fit. |
His notes list Boyle’s law as set in January 2020, Paper 3, Question 2 and January 2017, Paper 3, Question 2. These questions usually ask you to complete a table (1/V from V), plot P against 1/V, find the gradient with its unit, and give precautions and sources of error. The Paper 3 practice tab walks through each of those.